Sartorius FC Provozní pokyny

Procházejte online nebo si stáhněte Provozní pokyny pro Kuchyňské váhy Sartorius FC. Sartorius FC Operating instructions Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 140
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - Sartorius Factory Series

Operating InstructionsSartorius Factory SeriesFC and FCG ModelsElectronic Precision Scales98648-006-82

Strany 2 - Intended Use Contents

Getting Started Fastening the Display and Control Unit to the Front of the Weighing Platform§ Turn the scale over and place it on a cushioned surface

Strany 3 - Information

“FlexPrint” Printout FunctionPurposeThe YAD02IS “Nice Label Express” software from Sartorius lets you loaduser-defined label printing formats andthe c

Strany 4 - Operating Design

101Combining ApplicationsThe following table summarizes the possibilities for combination of the application programs described here. Each line stands

Strany 5 - T Data record

Using Applications in CombinationExample: Checkweighing with statistical evaluationYou want to check a piece count, and have the results that lie with

Strany 6

103Step Key (or instruction) Display/Output5. Initialize CheckweighingToggle to Checkweighing D6. Enter target, minimum andParam. soft keymaximum valu

Strany 7

Max6200 gMin 0.5 ge= 0.1 gd=0.01 gJF HSThere are 3 options for data output:– Output to the display and control unit– Output to a printer (generate a p

Strany 8

1051250é35=W*18.3*0.9gpcsas1 s2( A B C D H KL M NST COUNTING: nRef = 10 pcsRef.wt. too lightisoTST PT1/T1 S ID M+oo o Q q O lMeasured Value LineThis l

Strany 9 - FCG64EDE-S, FCG64EDE-H

PrintoutsPurposeThis function enables you to print outweights, other measured values and IDs.You can format the printout to meetdifferent requirements

Strany 10 - Getting Started

107ISO/GMP-compliant Printout/RecordYou can have the parameters pertainingto weighing conditions printed before(GMP header) and after (GMP footer)the

Strany 11 - Installing the Components

Interface DescriptionPurposeYour Factory scale comes equipped withan interface port for connection to acomputer or other peripheral device.You can use

Strany 12

109Line Format (Data Output Format)You can output the values displayed in the measured value line and the weightunit with or without a data ID codeExa

Strany 13

Installing the ComponentsFC06BBE-S§ Place the following components on the scale in the order given below:– Dust cover– Place the shield ring on the sc

Strany 14 - Configuration

Interface Description Data output example: + 1255.7 gPosition 12345678910111213141516+* * *1255. 7*g**CRLFPosition 1: Plus or minus sign or spacePosit

Strany 15

111Data Input FormatYou can connect a computer to your scale to send commands via the scale interface port to control scale functions and applications

Strany 16

Interface Description SynchronizationDuring data communication between thescale and an on-line device (computer),messages consisting of ASCII characte

Strany 17 - BAL.FUNC.)

113Pin Assignment ChartFemale Interface Connector12-contact, with screw-lock hardware for cable glandMale Connector RequiredType C091D, 12-pin round m

Strany 18 - Factory setting

Cabling Diagram (adapter cable – round – DB25-scale)Order No. YCC01-0016M3Female interface connector: 25-contact, D-Submini DB25S with screw lock hard

Strany 19

115Cabling DiagramFor connecting a computer or peripheral device to the scale using RS-232C/V24 for datatransfer over distances of up to 15 m (approx.

Strany 20

Error Codes and MessagesError codes and messages are displayed in the main display or text line for 2 seconds. The program then returns automatically

Strany 21

117Display/Problem Cause SolutionErr 31 Interface handshake interrupted Transmit XON, then CTSPrint fct. blocked (XOFF, CTS)Ref.wt. too light Error in

Strany 22

Care and MaintenanceServiceRegular servicing by a Sartoriustechnician will extend the service life ofyour scale and ensure its continuedweighing accur

Strany 23

119OverviewGeneral Views of the ScalesFC06BBE-S(0CE)The “0CE” suffix appended to the model number indicates a verified or verifiable scale modelNo. De

Strany 24 - Application)

Getting Started Connecting the Scale to AC Power§ Check the voltage rating and the plug design– If they do not match, contact your Sartorius office or

Strany 25

Overview 120General Views of the ScalesFC6CCE-H(0CE), FC2CCE-S(0CE), FC12CCE-S(0CE), FC6CCE-S(0CE) The “0CE” suffix appended to the model number indic

Strany 26

121General Views of the ScalesFCG34EDE-H, FCG34EDE-P, FCG16EDE-H, FCG12EDE-P, FCG64EDE-S, FCG64EDE-HNo. Designation1 Level indicator2 AC jack3 Interfa

Strany 27

SpecificationsStandard ModelsGeneral Specifications:AC power source/power requirements AC adapter, 230 or 115 V, +15% ... – 20%Frequency 48 – 60 HzAll

Strany 28

123Model FCG64EDE-H, FCG34EDE-H, FCG16EDE-H,FCG64EDE-H0UR* FCG34EDE-H0UR* FCG16EDE-H0UR*Readability g 0.1 0.1 0.1Weighing capacity kg 64 34 16Max. ove

Strany 29

Specifications Verified Models with EC Type ApprovalGeneral SpecificationsAC power source/power requirements AC adapter, 230 or 115 V, +15% ... –20%Fr

Strany 30 - PRINTOUT)

125Model FCG34EDE-H0CE FCG16EDE-H0CE FCG34EDE-P0CE FCG12EDE-P0CE FCG64EDE-S0CEType isoTEST in conjunction with BF BFAccuracy class * KKKKKScale interv

Strany 31 - Werkseinstellung

Dimensions (Scale Drawings)FC06BBE-S (0CE)FC6CCE-H (0CE), FC2CCE-S (0CE)All dimensions are given in millimeters.126

Strany 32 - Printout Configuration

127FC12CCE-S (0CE), FC6CCE-S (0CE)FCG64EDE-H, FCG34EDE-H, FCG16EDE-H, FCG34EDE-P, FCG12EDE-P, FCG64EDE-S (0CE)All dimensions are given in millimeters.

Strany 33 - N + 2003.13 g

Accessories (Options)Description Order no.Data InterfacesData interface RS485 X-bus for – FCG-EDE scales YDO01FG– FC-BBE/CCE scales YDO02FDual data in

Strany 34

129Description Order no.Cables and connectorsInterface cable for connecting printer YDP03-0CE YCC01-0019M3Interface cable, 5 m; round connector scale

Strany 35 - Displaying Info

Fastening an Antitheft Locking Device$ Models FC06BBE-S, FC6CCE-H, FC2CCE-S, FC12CCE-S, and FC6CCE-S only.To fasten an antitheft locking device, use t

Strany 36 - MP8 Interface Emulation

Accessories (Options) Description Order noSoftwareSartoConnect software program YSC01I(for transferring weighing data to a PC that runs under Windows®

Strany 37

131Declarations of ConformityThe C Mark on Sartorius EquipmentIn 1985, the Council of the European Community approved a resolution con-cerning a new a

Strany 42

IndexPageAccessories (options) 128Acoustic signal 23, 42Additional functions 91Animal weighing 61Antitheft device 13Application filter 18Application

Strany 43

Appendix: Entering the General PasswordEnter/Change Password● Select the Setup menu: Press M>SETUP SELECTIONis displayed● Select the user input fun

Strany 46

Example: Setting the Language to “U.S. Mode”Step Press key (or follow instructions) Display/Output1. Select “Setup” menu H2. Select “Language” Repeate

Strany 47

Sartorius AGWeender Landstrasse 94–10837075 Goettingen, GermanyPhone +49.551.308.0Fax +49.551.308.3289www.sartorius.comCopyright by Sartorius AG, Goet

Strany 48

Navigating in the Setup Menu (Examples)Example: Adapting the scale to “Extreme vibration” Step Press key(s)(or follow instructions) Display/Output1. S

Strany 49

Configuration Example: Setting date and timeStep Press key(s)(or follow instructions) Display/Output1. Select Setup menu; H, thenselect “Device param

Strany 50

Setting the Scale Functions (BAL.FUNC.)PurposeThis menu item enables you to configure the scale functions, i.e., to meet individual requirements bysel

Strany 51

Setting the Scale Functions (Overview)Setup - Calibration / Cal/isoTST key function External calibration/adjustment**; Scale adjustment with factory-

Strany 52

Setup – Weight unit 1* ο Grams /g**Scale ο Kilograms /kg**functions Carats /ct*Pounds /lb*Ounces /oz*Troy ounces /ozt*Hong Kong taels /tlh*Singapore t

Strany 53 - Application Programs

Intended Use ContentsThe Factory Series from Sartorius offersprecision scales for measuring mass(weight). The scales in this series havecapacities ran

Strany 54 - %: Weight unit 2)

Setting the Device Parameters (DEVICE)PurposeThis menu item enables you to configure the scale to meet individualrequirements by selecting predefinedm

Strany 55 - Counting A

§ New password: Enter the numbersand/or letters for the new password (8 characters max.)(If “none" is displayed, this means nopassword has been a

Strany 56

Setting the Device Parameters (DEVICE)Device Parameters (Overview)o factory setting√ user-defined settingSetup –DeviceparametersPassword: None Enter 8

Strany 57 - Qnt + 153 pcs

Setup –DeviceparametersInterfaces Function: Print keyexternal switch ο Tare keyCalibration keyF1 function key(Right soft key)Clear function key cF2 f

Strany 58 - Weighing in Percent

Setting the Application Parameters (Application)PurposeThis menu item enables you to configure the scale, i.e., adapt the scaleto your individual requ

Strany 59

Application Parameters (Overview)ο factory settings√ user-defined settingSetup – Application 1 Off (weighing only)Application (Basic settings) Toggle

Strany 60 - Prc + 98.37 %

Setting the Application Parameters (Application)Setup – Application 1 ο Counting Accuracy – Average ο Display accuracyApplication (Basic settings) pie

Strany 61 - Animal Weighing

Setup – Application 1 Calculation Decimal places in NoneApplication (Basic settings) calculated result 1 decimal placeparameters ο 2 decimal places3 d

Strany 62

Setting the Application Parameters (Application)Setup – Application 3 OffApplication (Data records)ο Totalizing Automatic storage o OffparametersOn, f

Strany 63

Setup – Application 3 Statistics Automatic storage ο OffApplication (Data records) On, first value at stability parametersparameters On, last value at

Strany 64 - Mul 1

Warning and Safety Operating DesignInformationThis scale has been constructed in accordance with the European Directivesas well as international regu

Strany 65 - Recalculation

Selecting the Printout Function (PRINTOUT)PurposeThis menu item enables you to configure the printout to meet yourindividual requirements by selecting

Strany 66

Printout Parameters (Overview)o factory setting√ user-defined settingSetup – Application- Stability parameter Without stability1)Printout defined ο W

Strany 67 - Minus soft key repeatedly

Printout ConfigurationPurposeThis menu item enables you to configureindividual printout formats. With the formulation, totalizing and statistics appli

Strany 68

Practical Example:Configure an Individual Printout for Counting Application to Include Dotted Line, Date/Time, Piece Count and Net WeightStep Press ke

Strany 69

Printout Configuration Data Items for the Printout:Parameter Display text Indiv. Comp. TotalBlank line** Blank line xxxDotted line** -------- xxxForm

Strany 70 - Calculation D

Displaying InfoPurposeThis menu item enables you to haveinformation displayed about the specificscale (“device”), as well as “FlexPrint”information.Di

Strany 71 - / soft key

MP8 Interface EmulationPurposeWith the MP8 interface emulation function, you can connect peripheraldevices of the MP8 generation thathave separate AC

Strany 72 - Checkweighing

MP8 Interface Emulation Parameters (Overview)ο Factory setting√ User-defined settingSetup – Scale operating see page 18MP8 menuInterfaceDevice parame

Strany 73

OperationBasic Weighing FunctionPurposeThe basic weighing function is alwaysaccessible and can be used alone or in combination with an application pro

Strany 74

Additional FunctionsIn addition to the functions:– alphanumeric input– taring (not during alphanumeric input)– printingyou can also access the followi

Strany 75 - Param. soft key

Operating DesignText Input§ To enter numbers: see the section on “Numeric Input”§ To enter letters or characters: press the a key> Letters are disp

Strany 76

Example W2Enter “ABC123” as sample ID ! Note:– The sample ID generally applies to one weighing operation only– The ID is deleted after data outputStep

Strany 77 - Time-Controlled Functions K

Device ParametersPasswordYou can enter a password to blockaccess to the operating menu and tothe functions for ID code input andexact calibration weig

Strany 78 - Stop soft key

Device ParametersDisplayYou can configure the display for yourindividual needs.The contrast can be adjusted in 5 levels:ContrastCharacters can be disp

Strany 79 - Totalizing

Calibration/Adjustment “isoTEST”PurposeCalibration is the determination of the difference between the weight readout and the true weight (mass) of a s

Strany 80

Calibration/Adjustment Preparation● Select the scale function for “calibration/adjustment”: press H● To select the Balance/scale functions: press the

Strany 81

PreparationSet the parameters for calibration and adjustment; e.g., with manual calibration/adjustmentStep Press key(s) Display/Output(or follow inst

Strany 82

Calibration/Adjustment Step Press key(s) Display/Output(or follow instructions)9. Confirm calibration andO soft key adjustment sequenceo = last setti

Strany 83 - Formulation

Internal Calibration/AdjustmentFirst set either Internalcal./adjustment orSelection mode (factory setting) in the Setup menu under “Scale functions: C

Strany 84

Calibration/Adjustment Selecting the Calibration/AdjustmentParameterThe setting Selection modemust be selected in the Setup menu under“Scale functions

Strany 85 - Comp1 + 42.88 g

External Calibration/Adjustment* withaUser-Defined Calibration WeightFirst set either Ext.cal./adj.;user-definedwt. or Selection mode(factory setting)

Strany 86

Bar Graph:The bar graph indicates how much of thescale’s capacity is “used up” by the currentload; during checkweighing, it indicatesthe control limit

Strany 87 - Statistics

Calibration/Adjustment isoCAL:Automatic Calibration and AdjustmentFirst set either On and resetthe application or Onwithout resetting theapp. (factory

Strany 88

Printout for Calibration/Adjustment You can have the results of a calibration/adjustment procedure printed out. You can configure whether the printout

Strany 89

Determination of the Repeatability (reproTEST)DefinitionRepeatability is the ability of the scale todisplay identical readouts when it is loadedsevera

Strany 90 - MR soft key

Application Programs!Using Verified Scales as Legal Measuring Instruments in the EU*:All application programs can be selectedon scales used as legal m

Strany 91 - 1 when there

Additional FunctionsIn addition to the functions for:– alphanumeric input,– taring (not during alphanumeric input),– printing (NUM print; S ID), you c

Strany 92 - PT1 + 400.00 g

Counting APurposeWith the Counting program you candetermine the number of pieces ofapproximately equal weight.You can use this application program in

Strany 93

Counting APreparationTo calculate a piece count, the average weight of one piece must be known. This average piece weight can be entered into the Coun

Strany 94

Practical ExampleDetermining an Unknown Piece Count; Weighing in the Preset Reference Sample QuantitySettings (changes in the factory settings require

Strany 95

Weighing in Percent BPurposeThis application program allows you toobtain weight readouts in percentwhich are in proportion to a referenceweight.Altern

Strany 96 - Delete soft key 4 times

PreparationTo calculate a value in percent, the reference percentage must be known. This value canbe entered into the weighing-in-percent program in o

Strany 97 - Saving Values Manually (M+)

Operating DesignTo set a parameter:● Press the Q or q soft key repeatedlyuntil the desired setting is selected (displayed inversely) ● Confirm your se

Strany 98 - Product Data Memory

Weighing in Percent BExamplesPractical Example: Weighing in Percent with Reference Weight Taken From Weight on ScaleSettings (changes in the factory s

Strany 99

Animal Weighing CPurposeUse this program to determine theweights of unstable samples (e.g., liveanimals) or to determine weights underunstable ambient

Strany 100 - “FlexPrint” Printout Function

Animal Weighing CPreparation● Turn on the scale: press e> Sartorius logo is displayed● Select the Animal weighing application in the Setup menu: pr

Strany 101 - Combining Applications

Practical ExampleDetermining Animal Weight With Automatic Start of 20 Subweighing Operations for Averaging; Automatic Printout of the Number of Subwei

Strany 102 - Start soft key

Animal Weighing CStep Key (or instruction) Display/OutputAfter 20 subweighing operationsthe arithmetic average (xNet) is display(mDef: no. of subweigh

Strany 103 - Qnt + 9 pcs

RecalculationPurposeWith this application program you cancompensate for over-poured componentsin formulation. If a component is over-poured whenweighi

Strany 104 - Data Output Functions

Recalculation Factory SettingsPrint application parameters (automaticoutput of application parameters): all valuesPrintout configuration:Line format:

Strany 105 - =W*18.3*0.9

Practical ExampleWhen weighing in formulation components, the second component is over-poured.Settings (changes in the factory settings required for t

Strany 106 - Printouts

Recalculation Step Key (or instruction) Display/Output… or enter the desired value 10.60 10.609. Confirm the new valueComp. soft key Comp1 + 25.08 gCo

Strany 107 - GLP soft key

Step Key (or instruction) Display/Output14. … and store Add.6 soft key Comp1 + 25.08 g(here, e.g., the 6th component) Comp2 + 10.73 gRekD + 1.01226

Strany 108 - Interface Description

Getting StartedStorage and Shipping Conditions– Do not expose the scale to extreme temperatures, jolts, impacts, vibration or moisture. Unpacking the

Strany 109

Calculation DPurposeWith this application program you cancalculate a weight value using an alge-braic equation. This can be used, forexample, to deter

Strany 110

Practical ExampleCalculate the gsm weight of paper: determine the gsm of a sheet of A4 paper with the dimensions 0.210 m + 0.297 m = 0.06237 m2. The g

Strany 111

Checkweighing HPurposeThis program is used to check whethera sample corresponds to a pre-set target value or is within a specific tolerance range. In

Strany 112

PreparationThe checkweighing program oftenrequires a target value for comparisonwith the current value. This target has a tolerance range, which is de

Strany 113 - Pin Assignment Chart

Checkweighing HPreparation● Turn on the scale: press e> Sartorius logo is displayed● Select the Checkweighing application in the Setup menu: press

Strany 114 - Connector – front view

Practical ExampleCheckweighing samples of 170 g, with an allowable tolerance of –5 g and +10 g. Printout of upper and lower tolerance limits. Weighed

Strany 115

Checkweighing HStep Key (or instruction) Display/Output9. Enter value for upper limit 1 8 0(170 g + 10 g) and storel soft key10. Weigh sample Place sa

Strany 116

Time-Controlled Functions KPurposeWith this application program, you can configure the scale to perform certain functions (e.g., automatic print-out o

Strany 117

78Practical ExampleDocument the amount of evaporation of a sample with defined surface, temperature and air pressure at preset intervals of 1 minute,

Strany 118 - Care and Maintenance

79Totalizing LPurposeThis application program acts as acumulative memory function.You can use the “Totalizing” applica-tion in combination with a prog

Strany 119 - Overview

Getting Started Mounting the Display and Control UnitYou can mount the display and control unit in one of 3 ways:– on the column, which is then fasten

Strany 120

Totalizing LPreparation● Turn on the scale: press e> Sartorius logo is displayed● Select the Totalizing application program in the Setup menu: pres

Strany 121 - General Views of the Scales

81Practical ExampleTotalize counted piecesSettings (changes in the factory settings required for this example):Setup: Application parameters: Applicat

Strany 122 - Specifications

Totalizing LStep Key (or instruction) Display/Output9. Store piece countM+ soft key10. Unload the scale Remove parts from the scale11. Place another l

Strany 123

83Formulation MPurposeWith this application program you can add weight values and calculatedvalues to a totalization memory ascomponents of a formula.

Strany 124

Formulation MPreparation● Turn on the scale: press e> Sartorius logo is displayed● Select the Formulation application program in the Setup menu: pr

Strany 125

85Practical ExampleWeighing in ComponentsSettings (changes in the factory settings required for this example):Setup: Application parameters: Applicati

Strany 126 - Dimensions (Scale Drawings)

Formulation MStep Key (or instruction) Display/Output8. Weigh in the next component Place components (here: 50.80 g) in containerComponents are stored

Strany 127

87StatisticsNPurposeWith this application program you canhave weight values and calculated val-ues totalized and statistically evaluated.The values de

Strany 128 - Accessories (Options)

StatisticsNPreparation● Turn on the scale: press e> Sartorius logo is displayed● Select the Statistics application program in the Setup menu: press

Strany 129

89Practical ExampleTotalize counted pieces and print out statisticsSettings (changes in the factory settings required for this example):Setup: Applica

Strany 130

Fastening the Display and Control Unit to the Front of the Weighing Platform or Mounting It Separately§ Turn the scale over and place it on a cushione

Strany 131 - Declarations of Conformity

Step Key (or instruction) Display/Output9. Store piece countM+ soft key10. Unload the scale Remove parts from the scale11. Place another load of parts

Strany 132

91Additional FunctionsSecond Tare Memory(Preset Tare)PurposeWith this function you can store theweight currently on the scale as a tareweight, or use

Strany 133

Additional Functions Practical ExampleDetermine the Contents of Bottles: Bottle weight = 400 g.Settings (changes in the factory settings required for

Strany 134

93Individual Identification Codes (ID)PurposeWith this function you can assign identifiers to values for documentationand printouts.You can use this e

Strany 135

Individual Identification Codes (ID) Preparation● Turn on the scale: press e> Sartorius logo is displayed● Select Extra function (F4) or Extra func

Strany 136

95ExampleInclude company address and sample lot number on the printout. Each ID line begins with the name. Print this ID for each net value.Settings (

Strany 137 - 40414243

Step Key (or instruction) Display/Output7. Repeat steps 5 and 6 for:ID2: LOCATIONID3: STREETID4: LOT8. Save settings, exit the Setup oo soft key twice

Strany 138

97Saving Values Manually (M+)PurposeWith this function you can load weightvalues and calculation results directlyfrom Application 1 (e.g., counting,we

Strany 139

Product Data MemoryPurposeWith this function you can enter, storeand load data records for initializationof applications, including user-defineddata.Y

Strany 140 - W6A000 · KT

99Practical ExampleCreate a New Base Data Record for Initializing the Checkweighing Program, Including: Target Value, Minimum, MaximumSettings (change

Komentáře k této Příručce